BRAND | Calectro |
Product | UG-5-AFR-230V-ST2 |
Description | air channel smoke switch |
Internal code | ONR4687413 |
Custom code | 85311030 |
Technical specification | 230 V AC The Uniguard smoke detector was developed and combined to detect smoke in ventilation ducts a smoke detector with an adapter system, with pipe and housing specifically for optimal airflow designed by the smoke detector. The UG-5 can be used on each side of the channel in four different Positions are installed: 0°, 90°, 180° and 270°. Patented Comes complete with air duct removal pipe, 0.6 m in length. Power supply: 230 V AC -15%, +10% Smoke detector type: UG-5-AFR-230V optical Max. power consumption: 30 mA operating temperature: -10°C to +55°C Maximum humidity: 99% RH Air speed range: 1 to 20 m/s Approvals: VdS G213014, CE, prEN-54-27 Smoke alarm unlocking via remote reset Relay output: potential-free Smoke alarm relays: two changeover contacts 250 V, 8A Service alarm: One 250 V, 5 A changeover contact System error alarm: One 250 V, 5 A changeover contact Air speed alarm: One changeover contact 250 V, 5 A LED on smoke detector: Green: service alarm (contamination) Red - smoke alarm LED on circuit board: Green: normal mode yellow - system error Yellow - air speed alarm Adapter housing: ABS Protection class: IP54 |
Please Contact Us to Order to offer competitive prices and delivery time for Calectro - UG-5-AFR-230V-ST2 air channel smoke switch number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Air duct smoke detector
Socket for smoke detector ST-P-DA/EVC-PY-DA
PTH 3202 obsolete, replacement CPS-24V, new replacement of CPS-24V - CPS-A
PRESSURE TRANSDUCER
Fire alarm switch
air duct smoke switch 24 V AC/DC
Venturi-Rohr Länge 600 mm für UG-5
console
Transparent cover for UG-2-A4O Uniguard obsolete alternative UG-5-AFR-24V
Transparent cover for optical smoke detector
protective housing
Steuergerät
Differential pressure transmitter -50 - +3500 Pa
UG-7-A60-24V , alternative is UG-5-AFR-24V
smoke detector
Complete unit including the alarm inside it
differential pressure transmitter
venturi tube
Leakage alarm for electrically conductive liquids
air duct smoke switch
Smoke detector base
pressure differentrial
Channel smoke detector
Replacement smoke alarm UG-5
Inherence sensor tape