UG-5-AFR-24V-ST2  - Calectro United States  Sales

BRAND Calectro
Product UG-5-AFR-24V-ST2
Description air duct smoke switch 24 V AC/DC
Internal code ONR2002464
Weight 1.3
Custom code 85311030
Technical specification Power supply: 24 V AC/DC -15%, +10% Smoke detector type: UG-5-AFR-24V optical Max current consumption: 220 mA operating temperature: -10°C to +55°C Max Humidity: 99% RH Air speed range: 1 to 20 m/s Approvals: VdS G213014, CE, pren-54-27 Smoke alarm release via remote reset Relay output: Potential free Smoke alarm relay: Two changeover contacts 250 V, 8A Service alarm: One changeover contact 250 V, 5 A System fault alarm: One changeover contact 250 V, 5 A Air speed alarm: One switching contact 250 V, 5 A LED on smoke detector: Green: Service alarm (contamination) red - smoke alarm LED on printed circuit board: Green: normal operation yellow - system error yellow - air speed alarm Adapter housing: ABS Protection class: IP54

Please Contact Us to Order to offer competitive prices and delivery time for Calectro - UG-5-AFR-24V-ST2 air duct smoke switch 24 V AC/DC number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Calectro

ST-P-DA-24VRL

Calectro Optical smoke switch 16-30 V DC, including short-circuit relay for use in raumen to fruezeitigen detections of Schwellbraenden fire and fire with smoke development .The sensor operates on the principle of scattered light, alarm relay with a potential-free changeover, including mounting base, the light transmitter and receiver are arranged in the Messa chamber so that the Lichtbuendel of the transmitter do not apply directly to the receiver kann.Erst the scattered light on suspended particles (Tyndall effect) reaches the receiver and is in an electrical signal umgesetzt.Eine green LED pollution (service), a red LED indicates the alarm. relay contact loads with 24 V / 1 A. Ambient temperature: minus 20 plus 50 degrees .Leistungsaufnahme: 2.64 watts; VDS test certificate: 205041

UG-3-A4-0

smoke detector

UG-3-O

Air duct smoke detector 24V DC

ST-P-DA-24VR

Optical Smoke Detector Insert

UG-5-AFR-230V-Z-ST2

Calectro Luftkanalrauchschalter

UG-5-AFR-230V

Duct Smoke Detector for Air Ventilation

UG-5-AFR-230V-Z

air duct smoke switch

STB-4SE-24VR

Socket for smoke detector ST-P-DA/EVC-PY-DA

UG-2-A20

Fire alarm switch

ST2

Venturi-Rohr Länge 600 mm für UG-5

UG-MB-75

console

UG-Cover-75

protective housing

ABAV-S3-230V

Steuergerät

CPS-A

Differential pressure transmitter -50 - +3500 Pa

UG-5-AFR-24V.

Complete unit including the alarm inside it

CPS-D-A

differential pressure transmitter

VR-0.6m

venturi tube

Other Category Brands

Contact us for request