CPS-D-A  - Calectro United States  Sales

BRAND Calectro
Product CPS-D-A
Description differential pressure transmitter
Internal code ONR3366557
Weight 0.092
Custom code 90321020
Technical specification Calectro differential pressure transmitter-100... +3500 Pa with display The CPS-D-A pressure sensor has a built-in differential pressure element, which for a high Accuracy and linearity are temperature-compensated. The differential pressure element and the output signal have a high resolution, which means that the pressure value is in steps of max. 1 Pa over the entire Measurement range (-100 to + 3500Pa) is presented. The desired function and measurement range are determined by set an illuminated display. The pressure measurement range determines at which measurement value the Start the output signal and when the maximum output signal should be given. output signal (0- 10V or 4-20 mA), K factor for volume measurement and the desired signal attenuation are also set via the display. CPS-D-A is manufactured from the factory for differential pressure measurement in the range 0-500 Pa, 0-10V output signal and medium signal attenuation (10 sec.) delivered. The measurement range can be indiscriminate from - 100 Pa to +3500 Pa, in steps of 50 Pa. CPS-D-A can measure volume/flow rate by setting the kFactor using, for example, blowers or measurement panels. The conversion formula The differential pressure in volume is: q = k x?? p. The K factor can be set with two decimals become. In addition, various units can be set: m³/h, m³//s and l/s. The The unit setting is only a display label and therefore does not perform a mathematical calculation of Measurement off. The measurement range can be indiscriminately from 0 to 32000, in steps of 100 to 3500 and in Steps of 500 from 3500 can be set. TECHNICAL DATA Supply voltage: 24V AC/DC ± 10% power consumption: 43 mA Output signal: 0-10V (>5 k? imp.) /4-20 mA Average attenuation: 3.10 or 20 sec Pressure ranges: Adjustable from -100 to +3500 Pa, in steps of 50 Pa Volume ranges: adjustable from 0 to +32000, in steps of 100 to 3500 and in steps of 500 from 3500 - Selectable standard symbols on the display: m³/h, m³//sec or l/sec - K factor: 0-9999.99 Accuracy: Normally ± 1% of measured pressure (@ <-100 Pa/>+100 Pa) Display: graphical LCD with backlight Ambient temperature: -20 to +50°C Cable inputs: 1xM16, 5-10 mm cable dimensions (WxHxD): 78 x90x40 m Weight: 92g 2 m hose and 2 nipples Protection class: IP54

Please Contact Us to Order to offer competitive prices and delivery time for Calectro - CPS-D-A differential pressure transmitter number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Calectro

UG-Cover-75

protective housing

ABAV-S3-230V

Steuergerät

CPS-A

Differential pressure transmitter -50 - +3500 Pa

UG-5-AFR-24V.

Complete unit including the alarm inside it

VR-0.6m

venturi tube

UG-3-A4-0

Air duct smoke detector 24 V AC/DC

CLA-24/230V

Leakage alarm for electrically conductive liquids

UG-3-A5-0

air duct smoke switch

STB-4 514010

Smoke detector base

PTH-3203

pressure differentrial

VDS CE24 V

Channel smoke detector

EVC-PY-DA-HS

Replacement smoke alarm UG-5

CLA-ST

Inherence sensor tape

UG-3-A40-VR06

Channel smoke switch

UG-3-0

air duct smoke switch

UG-3-A4O

detector

electronic card for UG-3-A40

an electronic card for a smoke detector that installed an air handling unit.

UG-3-0-VR06

air duct smoke switch

Other Category Brands

Contact us for request