BRAND | CD AUTOMATION |
Product | Typ: RS1ABCDEFGHIKL |
Description | Single-phase thyristor controllers REVO S series |
Internal code | ONR4478527 |
Technical specification | Item number RS1030-40SZ0000X1 REVOS-A-B-C-D-E-F-G-H-I-J-K J= X: user manual, German=standard (A) Load current (widthexexdepth) (with option) 030:30A (36 x 121 x 125 mm/36 x 121 x 185) 0.44 kg/0.61 kg 035:35A (36 x 121 x 125 mm/36 x 121 x 185) 0.44 kg/0.61 kg 040:40 A (36 x 121 x 125 mm/36 x 121 x 185) 0.44 kg/0.61 kg 060:60 A (93 x 269 x 185 mm) 3.40 kg 90:90 A (93 x 269 x 185 mm) 3.60 kg 120 120 A (93 x 273 x 185 mm) 3.60 kg 150 A (93 x 273 x 185 mm) 3.60 kg 180:180 A (93 x 273 x 185 mm) 3.60 kg 210:210 A (93 x 273 x 185 mm) 3.60 kg 300:300 A (137 x 520 x 270 mm) 15.00 kg 400:400 A (137 x 520 x 270 mm) 15.00 kg 500:500A (137 x 520 x 270 mm) 15.00 kg 600:600 A (137 x 520 x 270 mm) 15.00 kg 700:700 A (137 x 520 x 270 mm) 15.00 kg 800:800 A (137 x 560 x 270 mm) 17.20 kg (B) load voltage max 4:480 V 6:600 V 7:690 V (C) Mains voltage - devices =< 210A - without HB, without analog input 0: without - devices =< 210A - with HB and/or analog input 4:12-24 V ac/dc - Only for devices > 210A - The load voltage must are in the range of mains voltage 1:90-135 V 2:180 - 265 V 3:238 - 330 V. 5:342 - 528 V 6:540-759 V 7:540-759 V (D) input S: SSR V: 0-10Vdc A: 4-20 mA. (E) Operating mode - for all devices Z: ZC Zero Crossing - only in conjunction with analog input 4:BF4 8:BF8 6:BF16 (F) Repatriation 0: without (G) option - only for load currents =< 40A 0: no backup F: with fuse+holder Y: fuse + CT (current transformer) H: fuse + CT (current transformer) +HB (partial load error) X: fuse+CT (current transformer) +HB+ “flat wiring system”. - for load currents > 40A F: integrated fuse H: fuse + CT (current transformer) +HB (partial load error) (H) fan 0: without 1: with 110V fan (optionally from 120A) 2: with 220V fan (standard from 120A) 3: with 24VDC fan (from 120A) (I) UL 0: without UL L: with cUL (when available) (J) User manual 0: without 1: Italian 2: English 3: German (where available) 4: French (K) version 1: default |
Please Contact Us to Order to offer competitive prices and delivery time for CD AUTOMATION - Typ: RS1ABCDEFGHIKL Single-phase thyristor controllers REVO S series number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Solid state relays
Single-Thristorsteller series REVO S, Type: RS1ABCDEFGHIKL
Solid state relays
Single-phase thyristor series REVO S, Type: RS1ABCDEFGHIKL
Solid state relays
Single-phase thyristor series REVO S, Type: RS1ABCDEFGHIKL
Solid state relays
Zweiphasen - Thzristolsteller Serie REVO S
3PH, 300 Amps / 480 V max Voltage, 170 to 265 Volts auxiliary power supply, SSR Input,Zero Crossing used with SSR input
Series S Thyristor Controller
CD3000M 2PH/35A/400V/480V/170:265V/10KPot/BF008/NF/EM
CD3000M 2 Phases unit,35 Amps / 400V Operating voltage / 480Volts supply voltage,170 to 265 Volts auxiliary power supply
Thyristorsteller Serie S
Series S Thyristor Controller
CD3000S-1PH/45A/220/480V/12-24V/SSR/ZC/NF/HB
S series thyristor controller
Halter und Sicherung
MULTIDRIVE-3PH
MULTIDRIVE-3PH
SSR relay
Electric regulator SCR
Electric regulator SCR
Thyristorsteller
CD3000M 3PH/45A/100V/480V/170:265V/0-10V/BF008/NF/EM
CD3000M 3 Phases unit
CD3200 Phase angle thyristor unit
CD3200 Phase angle thyristor unit
Typ: CD3000S-2PH-10A-480V-SSR-UL
Thyristor plates Series S