BRAND | Fluke |
Product | Loop Fluke 789 |
Description | calibrator multimeter |
Internal code | ONR4956741 |
Technical specification | Diode test: 0.3mA @600mV Display type used: LCD Power source: LR6 AA 1.5V x4 battery Interfaz: IrDA Conforms to standard: EN 61010; CAT III 1000V; CAT IV 600V; EN 61243-3:2010 Dimensions: 203x100x50mm Continuity test: acoustic signal; <100Ω Measurement: AC voltage; DC voltage; frequency; DC current; resistance; AC current AC current measurement range: 0.001mA... 1A Resistance measurement range: 4kΩ; 400kΩ; 4MΩ; 40MΩ; 100mΩ... 400Ω DC current measurement range: 1A; 1µA... 30mA DC voltage measurement range: 400V; 1kV; 1... 400mV; 4V; 40V AC voltage measurement range: 400V; 1kV; 4V; 40V; 0.1... 400mV Frequency range measurement: 10MHz... 199.99Hz; 1999.9Hz; 19.99kHz Diode test: 0.3mA @600mV Battery/battery: LR6 AA 1.5V x4 battery Software:Fluke Connect (FLK-IR3000FC) Frequency range measurement accuracy: ± (0.005% +1 digit) AC current measurement accuracy: ± (1% + 2 digit) DC voltage measurement accuracy: ± (0.1% + 1 digit) DC current measurement accuracy: ± (0.2% + 2 digit) AC voltage measurement accuracy: ± (1.2% + 4 digit) Resistance measurement accuracy: ± (0.2% +1 digit) |
Please Contact Us to Order to offer competitive prices and delivery time for Fluke - Loop Fluke 789 calibrator multimeter number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Pressure calibrator (7 bar)
Druckkalibrator (20 bar)
Druckkalibrator (34.7 bar)
Druckkalibrator (69 bar)
Druckkalibrator (103.4 bar)
Druckkalibrator (207 bar)
Druckkalibrator (345 bar)
Druckkalibrator (690 bar)
Calibrator Pressure
Druckkalibrator (7 bar)
Pressure calibrator
calibrator
Eigensicherer Druckkalibrator (100 psig bzw. 7 bar)
Intrinsically Safe Pressure Calibrator
Pressure calibrator with an electric pump
Druckkalibrator mit elektrischer Pumpe (7 bar)
Druckkalibrator mit elektrischer Pumpe, 2 bar
Druckkalibrator mit elektrischer Pumpe, 10 bar
Electric Pressure Calibrator
Druckkalibrator mit zwei Relativdrucksensoren, 1,1 bar, 6,9 bar
Druckkalibrator mit zwei Relativdrucksensoren, 1,1 bar, 20 bar
Druckkalibrator mit zwei Relativdrucksensoren, 1,1 bar, 34,5 bar
Druckkalibrator mit zwei Relativdrucksensoren, 1,1 bar, 69 bar
Druckkalibrator mit zwei Relativdrucksensoren, 1,1 bar, 100 bar
Druckkalibrator mit zwei Relativdrucksensoren, 1,1 bar, 200 bar
Druckkalibrator mit zwei Relativdrucksensoren, 1,1 bar, 345 bar
Druckkalibrator mit zwei Relativdrucksensoren, 2,5 bar, 6,9 bar
Druckkalibrator mit zwei Relativdrucksensoren, 2,5 bar, 20 bar
Druckkalibrator mit zwei Relativdrucksensoren, 2,5 bar, 34,5 bar
Druckkalibrator mit zwei Relativdrucksensoren, 2,5 bar, 69 bar