BRAND | Vega |
Product | BR52.CMGP1RZKMXS |
Description | Pressure transmitter with CERTEC® measuring cell |
Internal code | IMP519369 |
Weight | 1 |
Technical specification | Application area The VEGABAR 52 pressure transmitter can be used universally for measurement of gases, vapours and liquids. Also substances such as sand can be easily measured through the abrasion-resistant ceramic measuring cell. The VEGABAR 52 offers maximum reliability and safety and can be used in all industries. Your benefit - High plant availability by maximum overload and vacuum resistance of the ceramic measuring cell - Measurement down to the last drop through smallest measuring ranges with high reliability - Low maintenance costs through wear-free ceramic measuring cell Approval CM : ATEX II 1G, 1/2G, 2G Ex ia IIC T6 + Ship approval Process fitting / Material GP : Thread G½, inner G¼ (ISO228-1) PN160 / 316L Concept/Wetted meas. cells sealing/Process temperature 1 : Single / FKM (A+P 70.16) / -40...120°C Measuring unit for pressure : bar Pressure / Measuring range R : rel. / -1...5.0bar (-100...500kPa) Factor overload resistance measuring cell : 13,000 Electronics Z : 4 ... 20 mA Unit : bar Initial value : -1,000 Final value : 5,000 Housing / Protection K : Plastic single chamber / IP66/IP67 Cable entry / Cable gland / Plug connection Display/adjustment module (PLICSCOM) M : M20x1.5 / with / without X : without Accuracy class S : 0.20% Additional equipment : without Menu language : EN - English Operating instructions in : EN - English Number of operating instructions : 1 Supply certificates : with goods Customs tariff number (HS code) : 90262020 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Vega - BR52.CMGP1RZKMXS Pressure transmitter with CERTEC® measuring cell number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Radar sensor for continuous level measurement of bulk materials
VEGAPULS 68 radar sensor for continuous level measurement of bulk materials
Generation of devices:
Generation of devices: plics®plus Approval XX: no Measuring range max. : 75,000 m Version / Material E: with horn antenna Ø95 mm / 316L Process connection / material 1Q: swivel bracket flange DN100 PN16 / 316L Seal / 2 Process temperature: FKM (SHS FPM 70C3 GLT) and PTFE / -40 ... 130 ° C Electronics H: two-wire 4 ... 20 mA / HART Housing / Protection A: aluminum / IP66 / IP68 (0.2 bar) Cable entry / gland / connector M: M20x1,5 / with / without Display adjustment module PLICSCOM A: Built Additional equipment K: flushing connection Language of the menu: DE - German Operating instructions in: DE - German Number of Operating Instructions: 5
(VEGAPULS 68 Radar sensor for continuous level measurement of solids)
Antenna cover for VEGAPULS SR68 / 68 The antenna cover can be retrofitted and prevents dust deposits Antenna system. All necessary mounting hardware is included. Cover for antenna / Material / Max. D: horn antenna (ø75mm) / PP / + 80 ° C Customs tariff number (HS code): 90319085
Antenna cover for VEGAPULS SR68 / 68 Cover for antenna / Material / Max. E: horn antenna (Ø95mm) / PP / + 80 ° C Customs tariff number (HS code): 90319085
antenna cover
Antenna cover made of plastic or flexible Gore® membrane. Cover for antenna / Material / Max. F: Horn ø75 mm / PTFE / 130 ° C Operating instructions in: DE - German Number of Operating Instructions: 1
Antenna cover for VEGAPULS SR68/68
TRANSMİTTER
Electronics VEGAPULS series 60 plics® Generation of devices: plics® Device variant 60S: Universal embodiment VEGAPULS67 / 68 Electronics H: two-wire 4 ... 20 mA / HART for device approval X: XX with programming: no Operating instructions in: DE - German Number of Operating Instructions: 3
Generation of devices: plics®plus Approval XX: no Version / Material D: with horn antenna ø75mm / 316L Process fitting / Material 1P: swiveling holder with flange DN80 / 316L Seal / 2 Process temperature: FKM (SHS FPM 70C3 GLT) and PTFE / -40 ... + 130 ° C Electronics H: two-wire 4 ... 20 mA / HART Housing / Protection A: aluminum single chamber / IP66 / IP68 (0.2 bar) Cable entry / gland / connector M: M20x1,5 / with / without Indicating / adjustment module PLICSCOM A: Built Additional equipment X: no Range: 30,000 m Language of the menu: DE - German Operating instructions in: DE - German Number of Operating Instructions: 1
(Radar sensor for continuous level measurement of solids)
(VEGAPULS SR 68 Radar sensor for continuous level measurement of solids)
Radarsensor zur kontinuierlichen Füllstandmessung
Vega Plus 66 Radar Level Transmitter
HARD CPU BOARD 238392
VEGASEL 643 auxiliary level switch and signal conditioning
Auxiliary level switch and signal conditioning
VEGASWING 51 - Vibrating level switch for liquids
TRANSDUCER CONNECTION MODULE (minicom) TO BE USED IN TRANSDUCERS.
Radar sensor for continuous level measurement of bulk materials
(Vibration level switch for liquids with tube extension Admission CA: ATEX II 1G, 1 / 2G, 2G Ex ia IIC T6 + WHG Process connection / GBV material: Thread G¾ PN64, DIN3852-A / 316L Adapter / process temperature X: No / -50 ... + 150 ° C Housing / Protection / Cable gland P: plastic single chamber / IP66 / 67 / M20x1,5 Electronics Z: two-wire (8 / 16mA) 12 ... 36V DC Length (from the sealing surface): 100,000 mm)
(Vibration level switch for liquids with tube extension)