C2I-IIU-33-K   - Bronkhorst United States  Sales

BRAND Bronkhorst
Product C2I-IIU-33-K
Description Valve for liquid or gas flow rate: (0) ... 50 g / min H2O
Internal code ONR220047
Weight 1

Please Contact Us to Order to offer competitive prices and delivery time for Bronkhorst - C2I-IIU-33-K Valve for liquid or gas flow rate: (0) ... 50 g / min H2O number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in United States Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Bronkhorst

C5I-ITU-99-K- identical with SN: B10200029B

(Type: C5I-ITU-99-K *** Bauglich with SN: B10200029B *** Flow: (0) ... 1 ... 50 g / min of water + solvent (Density 930 kg / m³, viscosity: 1 mPas at 0 ° C and 1013 mbara) Pressure: 2 bar overpressure Pressure: 0 ... 0.5 barg Mediums- / Ambient temperature: 50 ... 70 ° C Execution: N.C. Connection Input: 3/8 "Tri-Clamp Connection output. 3/8 "Tri-Clamp Material seal: Kalrez Media wetted parts: stainless steel 1.4404 (SS 316) Mounting position: any Temperature limits: -10 ° C ... + 70 ° C)

E-7500-GDD

Digital Power Supply/Read-out System

Elektronischer Durchflussmesser Typ MV-302 mit Nadelventil

- Measuring range 1: 0.02 ... 2 ln / min air, N2, O2, CO2, CO, N2O 0.04 ... 4 ln / min Ar, 0.01 ... 1 ln / min CH4, C3H8, C4H10 - Measuring range 2: 0.01 ... 1 ln / min air, N2, O2, CO, CO2, N2O 0.005 ... 0.5 ln / min CH4, C3H8, ... C4H10,0,02 2 ln / min Ar - Measuring range 3: 0.01 ... 0.5 ln / min air, N2, O2, CO, CO2, N2O 0.02 ... 1 ln / min Ar, 0.005 ... 0.2 ln / min CH4, C3H8, C4H10 - Measuring range 4: 0.01 ... 0.2 ln / min air, N2, O2, CO, CO2, N2O 0.02 ... 0.5 ln / min Ar, 0.005 ... 0.1 ln / min CH4, C3H8, C4H10 Accuracy: ± 2% RD greater than 50% of the max. capacity ± 1% RD + 0.5% FS for small flows Repeatability: less than 0.1% FS Pressure range: 0 ... 10 bar g Temperature range: 0 ... 50 ° C Connections: G 1/4 "BSPP female Electrical connection: 8-pin RJ45 Power supply: 15 ... 24 Vdc Exit: - analog: 0 ... 5 Vdc - digital: RS232 RS485 (Modbus ASCII / RTU)

Elektronischer Durchflussmesser Typ MV-304 mit Nadelventil

- Measuring range 1: 0.2 ... 20 ln / min air, N2, O2, CO2, CO, N2O 0.4 ... 40 ln / min Ar, 0.1 ... 10 ln / min CH4, C3H8, C4H10 - Measuring range 2: 0.1 ... 10 ln / min air, N2, O2, CO, CO2, N2O 0.05 ... 5 ln / min CH4, C3H8, C4H10,0,2 20 ... ln / min Ar - Measuring range 3: 0.05 ... 5 ln / min air, N2, O2, CO, CO2, N2O 0.1 ... 10 ln / min Ar, 0.02 ... 2 ln / min CH4, C3H8, C4H10 - Measuring range 4: 0.04 ... 2 ln / min air, N2, O2, CO, CO2, N2O 0.08 ... 5 ln / min Ar, 0.02 ... 1 ln / min CH4, C3H8, C4H10 Accuracy: ± 2% RD greater than 50% of the max. capacity ± 1% RD + 0.5% FS for small flows Repeatability: less than 0.1% FS Pressure range: 0 ... 10 bar g Temperature range: 0 ... 50 ° C Connections: G 1/4 "BSPP female Electrical connection: 8-pin RJ45 Power supply: 15 ... 24 Vdc Exit: - analog: 0 ... 5 Vdc - digital: RS232 RS485 (Modbus ASCII / RTU)

F-103EI-AGD-00-V

flow meter

F-106DI-AGD-02-V

Digit. Mass Flow Meters Calibration curve 1: (0) ... 24 ... 1200 m³n / h N2 Calibration 2-8: Optional Pressure: 3 barg Mediums- / ambient temperature: 25 ° C Measurement accuracy: ± 1% of full scale * Mounting between flanges: DN 100 In scheme: valve is closed in the rest position Interfaces: Analog, RS232 Power supply:. 8 pol.Amphenol Output signal: 4 ... 20 mA Power supply: + 15 Vdc .... 24 Vdc, 100 mA plus 250 mA. for combination with control valve Pressure: PN 16 Seal material: Viton Repeatability: better than 0.2% of reading Media wetted parts: stainless steel 1.4404 (SS 316) Installation position: horizontal Temperature limits: -10 ° C ... + 70 ° C Protection: IP65, (ATEX CAT 3, Zone II (II 3 G / D Ex nA optionally possible II T4) Centering for between flanges: Included Factory calibration certificate 3 points inclusive, (5 points or DIN 17025 optional)

F-111AI-50K-AGD-44-V

Mass Flow Meters Measuring range: (0) ... 60 ... 3000 ln / h N2 Measuring range: 2-8: optional Pressure: 1 ... 10 bara Mediums- / Ambient temperature: 15 ... 35 ° C Accuracy of measurement: ± 0.8% v. Measured value ± 0.2%. full scale based on calibration * Pressure: PN 100, test pressure 1.5 x operating pressure Interfaces: Analog, RS232 Analog signal 4 ... 20 mA Power supply: + 15 ... 24 Vdc Connection input: 12 mm compression fitting Connection output: 12 mm compression fitting (others on request) Seal material: Viton Media wetted parts: stainless steel 1.4404 (SS 316) Installation position: horizontal Protection: IP65, (ATEX CAT 3, Zone II (II 3 G / D Ex nA optionally possible II T4) Factory calibration certificate 3 points inclusive, (5 points or DIN 17025 optional)

F-112AC-M10-AAD-00-V

(Digital mass flowmeter calibration curve 1 (0) ... 0.1 ... 5 m³n / h CH4 Calibration 2-8: Optional Pressure: 150 mbarg Mediums- / Ambient temperature: 20 ° C Accuracy of measurement: ± 0.8% v. Measured value ± 0.2%. final value, based on calibration * Pressure: min PN 100, test pressure. 1.5 x form Interfaces: Analog, RS232 Analog signal: 0 ... 5 Vdc Power supply: + 15 ... 24 Vdc Connection Input: 1/4 "BSPP Connection output: 1/4 "BSPP Seal material: Viton Media wetted parts: stainless steel 1.4404 (SS 316) Mounting position: any, from 10 barg horizontally Factory calibration certificate 3 points inclusive, (5 points or DIN 17025 optional))

F-113AI-1M0-AGD-44-V

Measuring range: (0) ... 840 ... 50 000 ln / min N2 Measuring range: 2-8: optional Pressure: 1 ... 10 bara Mediums- / Ambient temperature: 15 ... 35 ° C Accuracy of measurement: ± 0.8% v. Measured value ± 0.2%. full scale based on calibration * Pressure: PN 100, test pressure 1.5 x operating pressure Interfaces: Analog, RS232 Analog signal: 4 ... 20 mA Power supply: + 15 ... 24 Vdc Connection input: 12 mm compression fitting Connection output: 12 mm compression fitting (others on request) Seal material: Viton Media wetted parts: stainless steel 1.4404 (SS 316) Installation position: horizontal Protection: IP65, (ATEX CAT 3, Zone II (II 3 G / D Ex nA optionally possible II T4) Factory calibration certificate 3 points inclusive, (5 points or DIN 17025 optional)

F-202EV-AGD-22-K

Massedurchflussregler

F-231M-AAD-33-V

(Digital mass flow controllers)

M14-RGD-99-O

flowmeter control valve, IIU/IIW/IXU Ui=15V Imax_0.30 A Tamb. -10 to 50oC mini cori flow mass flowmeter

MV-394 HZ

GAS FLOW METER

MV-396 HZ

GAS FLOW METER

TPH-003F M3202823A

air flowmeter, 2400 IN/H AIR, 8..12BAR(G)0..9...5BAR

Typ: F-231MI-AGD-22-V ( M12204133A)

Digitaler Massedurchflussregler

MV-304

Electronic flow controller

F-206AI-AGD-00-V

digital mass flow controller

Typ: L23V12-AGD-11-K

mass flow controller

F-230MI

Mass Flow Meter

F-203AI-1M0-AGD-99-V

Massedurchflussregler

F-203AV-1M0-AGD-99-V

Digitaler Massedurchflussregler

F-201CI-5K0-AGD-33-V

Industrial Style Thermal Mass Flow Controller for Gases

F-201C-AGD-99-V

Flow meter

Contact us for request